$50 = Free Global Delivery

4410.0215 T12 221S 2 1 Pole Thermal Circuit Breaker - 240VAC/28VDC 2A 1kA - Threaded Neck Manual ON/OFF Switch with Quick Connect Terminals & Auxiliary Contact - Perfect for Home Appliances, HVAC Systems and Industrial Electrical Equipment Protection
4410.0215 T12 221S 2 1 Pole Thermal Circuit Breaker - 240VAC/28VDC 2A 1kA - Threaded Neck Manual ON/OFF Switch with Quick Connect Terminals & Auxiliary Contact - Perfect for Home Appliances, HVAC Systems and Industrial Electrical Equipment Protection

4410.0215 T12 221S 2 1 Pole Thermal Circuit Breaker - 240VAC/28VDC 2A 1kA - Threaded Neck Manual ON/OFF Switch with Quick Connect Terminals & Auxiliary Contact - Perfect for Home Appliances, HVAC Systems and Industrial Electrical Equipment Protection

$32.28 $58.7 -45%

Delivery & Return:Free shipping on all orders over $50

Estimated Delivery:7-15 days international

People:29 people viewing this product right now!

Easy Returns:Enjoy hassle-free returns within 30 days!

Payment:Secure checkout

SKU:80112213

Guranteed safe checkout
amex
paypal
discover
mastercard
visa

Product Description

Schurter, 4410.0215 T12-221S-2, 1 Pole Thermal Circuit Breaker for Electrical Appliance, 240VAC/28VDC, 2 Amp, 1kA, Threaded neck type, Manual ON/OFF Type, Quick Connect Terminals, w/ Auxiliary Contact

Thermal Circuit Breakers are used for over-current (overload and short-circuit) protection of Electrical Appliances, and as a disconnector in case of equipment failure/malfunction

Description

  • Threaded neck type
  • Thermal circuit breaker
  • 1-pole with Auxiliary Contact- Motors
  • Reset type
  • Quick connect terminals 6.3 x 0.8 mm

Features :

  • < 3mS Trip Delay Time
  • 1 Pole Disconnect with Auxiliary Contact
  • 1kA Short Circuit Rating
  • Suitable for 500VDC Isolation

Applications:

  • Power Tools
  • Household Equipment
  • Power Supplies and Chargers
  • Industrial Appliances

Standards :

  • IEC 60934
  • 2 x Ir: 500 Cycles
  • 500VDC Insulation Resistance
  • 1.5kV (50Hz) Dielectric Strength
  • Overload @ 6 x Ir Cos φ 0.6 IEC: min 40 trip
  • @ 1.5 x Ir, cos φ 0.75 Allowable UL / CSA: min. 50 trips
    Specification
    Schurter Part Number4410.0215 T12-221S-2
    Functions1 Pole Thermal Circuit Breaker with Aux Contact, Manual ON/OFF Type
    Nominal Voltage240VAC @ 50Hz or 28VDC
    Nominal Current Range2 Amp RMS
    Trip Delay Time< 3ms
    Rated Frequency50/60 Hz
    Operating Temperature-5 to 60 Deg C
    Insulation Resistance500VDC
    Dielectric Strength4kV (50Hz)
    Short Circuit Current1kA
    ApprovalsUL, CSA
    StandardsIEC 6094
    Weight10g
    Enclosure MaterialUL94
    Factory Pack Qty1

    Datasheet