$50 = Free Global Delivery

Fluke 5606 Full Immersion PRT Thermometer - 50mm Probe, 200°F to 160°C Temperature Range, Long Cable - Ideal for Industrial, HVAC, and Laboratory Temperature Measurement
Fluke 5606 Full Immersion PRT Thermometer - 50mm Probe, 200°F to 160°C Temperature Range, Long Cable - Ideal for Industrial, HVAC, and Laboratory Temperature Measurement

Fluke 5606 Full Immersion PRT Thermometer - 50mm Probe, 200°F to 160°C Temperature Range, Long Cable - Ideal for Industrial, HVAC, and Laboratory Temperature Measurement

$873.95 $1589 -45%

Delivery & Return:Free shipping on all orders over $50

Estimated Delivery:7-15 days international

People:28 people viewing this product right now!

Easy Returns:Enjoy hassle-free returns within 30 days!

Payment:Secure checkout

SKU:92734698

Guranteed safe checkout
amex
paypal
discover
mastercard
visa

Product Description

(item no. 4180640, 4180657, 4180669, 4180678, 4180684, 4180691, 4180706, 4180714, 4180723, 4180738)

Product overview

The 5606 Full Immersion PRTs are designed to perform in extreme environments where both the transition junction and the lead wires are required to withstand temperatures covering the entire operating range of the probe. (“Immersion" in this case simply means exposure to temperatures other than ambient and does not necessarily refer to the medium to which the PRT and its components are subjected.)

Applications where “full immersion" of probe, transition junction, and lead wire is required can include calibration or validation of sensors used in laboratory or bio freezers, walk-in refrigerators, autoclaves, ovens, stability test chambers, furnaces or incubators. Other applications might include IQ/OQ/PQ qualification procedures, temperature mapping, or data logging in temperature controlled spaces or environmental chambers.

Features

  • -200 °C to 160 °C
  • Calibration accuracy of ± 0.05 °C
  • Transition junction and lead wires can withstand full PRT temperature range
  • Unique probe seal of 5606 prevents ingress of moisture
  • Calibration not included; NVLAP-accredited calibration optional

 

Specifications

General Specifications
Temperature range-200°C to 160°C
Nominal resistance at 0.01°C100 Ω ±0.1 Ω
Temperature coefficient0.00385 Ω/Ω/°C
Accuracy1±0.04°C at 0.01°C
±0.06°C at 160°C
Short-term repeatability2±0.03°C at 0.01°C
±0.04°C at 160°C
Drift3±0.03°C at 0.01°C
±0.04°C at 160°C
Hysteresis±0.015°C
Sheath length50 mm ±5 mm
(2 in ±0.2 in)
Sheath diameter3.1 mm ±0.1 mm (1/8 in ±0.004 in)
Sheath material316 SST
Transition junction temperature range4-200°C to 160°C
Transition junction dimensionsNo transition
Sensor length30 mm ±3mm (1.2 in ±0.1 in)
Sensor location3 mm ±1 mm from tip (1.2 in ±0.04 in)
Minimum insulation resistance20 MΩ at 23°C
Minimum immersion lengthFull immersion
Maximum immersion depth in liquid mediumFull immersion
Maximum immersion depth in dry MediumFull immersion
Response time512 seconds typical
Self heating (in 0°C bath)±0.003°C
Lead-wire cable typeEnameled copper wire
Lead-wire length2.4 meters (8 ft)
Lead-wire temperature range160°C
CalibrationCalibration not included. NVLAP accredited calibration available. See ordering information.
1. Includes calibration and 100 hr drift (k = 2).
2. Three thermal cycles from min to max temp, includes hysteresis, 95% confidence (k = 2).
3. After 100 hours at max temp, 95% confidence (k = 2).
4. Temperatures outside this range will cause irreparable damage.
5. Per ASTM E 644.
Calibration Uncertainty
Temperature-197°C1924 Calibration Uncertainty6 0.03°C
Tolerance w/out Calibration7 0.4°C
 -38°C1924 Calibration Uncertainty6 0.03°C
Tolerance w/out Calibration7 0.2°C
 0°C1924 Calibration Uncertainty6 0.03°C
Tolerance w/out Calibration7 0.1°C
 100°C1924 Calibration Uncertainty60.045°C
Tolerance w/out Calibration7 0.3°C
 157°C1924 Calibration Uncertainty6 0.05°C
Tolerance w/out Calibration7 0.4°C
6. Lab code 200348-0
7. Each PRT includes a certificate with a measured R0 value.
An uncalibrated 5606 or 5607 meets ASTM E 1137 Grade A Classification of Tolerances.
Use the coefficients below to achieve the tolerances listed in the “No Calibration” column or calculate the Grade A tolerance using the following formula:
Grade A = ±[0.13 + 0.0017|t|]°C
where: |t| = value of temperature (°C) without regard to sign. See ASTM E 1137.
R0: Enter the R0 value provided
A: 3.9083 x 10–3
B: –5.775 x 10–7
C: –4.183 x 10–4

  

Models: 5606 Full Immersion PRT

Fluke 5606-50-X
Fluke 5606-50-X Full Immersion PRTs
Full Immersion PRTs Probe, 50 mm, –200 to 160°C

† X = termination. Specify “A” (INFO-CON for 914X), “B” (bare wire), “D” (5-pin DIN for Tweener Thermometers), “G” (gold pins), “I” (INFO-CON for 1521 or 1522), “J” (banana plugs), “L” (mini spade lugs), “M” (mini banana plugs), “P” (INFO-CON for 1523 or 1524), or “S” (spade lugs).